Seminars in Nuclear Medicine
Volume 33, Issue 3 , Pages 180-192, July 2003

Software for image registration: Algorithms, accuracy, efficacy☆☆

From the Department of Medical Physics and Department of Nuclear Medicine & Ultrasound, Westmead Hospital, Sydney, Australia; and the Department of Applied Physics, University of Technology, Sydney, Australia

Abstract 

Image registration is finding increased clinical use both in aiding diagnosis and guiding therapy. There are numerous algorithms for registration, which all involve maximizing a measure of similarity between a transformed floating image and a fixed reference image. The choice of the similarity measure depends, to some extent, on the application. Methods based on the use of the joint intensity histogram have become popular because of their flexibility and robustness. A distinction is made between rigid-body and non-rigid transformations. The latter are needed for inter-subject registration or intra-subject registration in cases where the region of the body of interest is not considered rigid. Non-rigid transformation is normally achieved using a global model of the deformation but can also be defined by a set of locally rigid transformations, each constrained to a small block in the image. There is scope for further research on the incorporation of appropriate constraints, especially for the application of non-rigid transformations to nuclear medicine studies. Most of the initial practical concerns regarding image registration have been overcome and there is increasing availability of commercial software. There are several approaches to the validation of registration software, with validation of non-rigid algorithms being particularly difficult. Studies have demonstrated the accuracy on the order of half a pixel for both intra- and inter-modality registration (typically 2 to 3 mm). Although hardware-based registration has now become possible by using dual-modality instruments, software-based registration will continue to play an important role in nuclear medicine. © 2003 Elsevier Inc. All rights reserved.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Address reprint requests to Brian F. Hutton, Department of Medical Physics, Westmead Hospital, Westmead, NSW 2145, Australia.

☆☆ 0001-2998/03/3303-0013$30.00/0

PII: S0001-2998(03)70004-X

doi:10.1053/snuc.2003.127309

Seminars in Nuclear Medicine
Volume 33, Issue 3 , Pages 180-192, July 2003