Seminars in Nuclear Medicine
Volume 38, Issue 1 , Pages 47-55 , January 2008

Measurement of Glomerular Filtration Rate With Magnetic Resonance Imaging: Principles, Limitations, and Expectations

  • Nicolas Grenier, MD

      Affiliations

    • Laboratoire d’Imagerie Moléculaire et Fonctionnelle, UMR-CNRS 5231 Université Victor Segalen-Bordeaux 2, Bordeaux, France.
    • Service d’Imagerie Diagnostique et Interventionnelle de l’Adulte, Groupe Hospitalier Pellegrin, Bordeaux, France.
    • Corresponding Author InformationAddress reprint requests to Nicolas Grenier, MD, Service d’Imagerie Diagnostique et Interventionnelle de l’Adulte, Groupe Hospitalier Pellegrin, Place Amelie Raba Leon, 33076 Bordeaux, France.
  • ,
  • Iosif Mendichovszky, MD, PhD

      Affiliations

    • Radiology & Physics Unit, UCL Institute of Child Health, London, United Kingdom.
  • ,
  • Baudouin Denis de Senneville, PhD

      Affiliations

    • Laboratoire d’Imagerie Moléculaire et Fonctionnelle, UMR-CNRS 5231 Université Victor Segalen-Bordeaux 2, Bordeaux, France.
  • ,
  • Sébastien Roujol, MSc

      Affiliations

    • Laboratoire d’Imagerie Moléculaire et Fonctionnelle, UMR-CNRS 5231 Université Victor Segalen-Bordeaux 2, Bordeaux, France.
  • ,
  • Pascal Desbarats, PhD

      Affiliations

    • Laboratoire Bordelais de Recherche en Informatique (LaBRI), UMR-CNRS 5800 Université Bordeaux 1, Bordeaux, France.
  • ,
  • Michael Pedersen, PhD

      Affiliations

    • MR Research Center, Institute of Clinical Medicine, University of Aarhus, Aarhus, Denmark.
  • ,
  • Kevin Wells, PhD, CEng, CPhys, MInstP

      Affiliations

    • CVSSP, Faculty of Electronics and Physical Sciences, University of Surrey, Surrey, United Kingdom.
  • ,
  • Jorgen Frokiaer, MD, DMSc

      Affiliations

    • MR Research Center, Institute of Clinical Medicine, University of Aarhus, Aarhus, Denmark.
    • Department of Clinical Physiology and Nuclear Medicine, Aarhus University Hospital–Skejby, Aarhus, Denmark.
  • ,
  • Isky Gordon, FRCR, FRCP

      Affiliations

    • Radiology & Physics Unit, UCL Institute of Child Health, London, United Kingdom.

References 

  1. Bennett HF, Li D. MR imaging of renal function. Magn Reson Imaging Clin N Am. 1997;5:107–126
  2. Bokacheva L, Rusinek H, Chen Q, et al. Quantitative determination of Gd-DTPA concentration in T1-weighted MR renography studies. Magn Reson Med. 2007;57:1012–1018
  3. Pedersen M, Shi Y, Anderson P, et al. Quantitation of differential renal blood flow and renal function using dynamic contrast-enhanced MRI in rats. Magn Reson Med. 2004;51:510–517
  4. Rusinek H, Lee VS, Johnson G. Optimal dose of Gd-DTPA in dynamic MR studies. Magn Reson Med. 2001;46:312–316
  5. Buckley DL, Shurrab AE, Cheung CM, et al. Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects. J Magn Reson Imaging. 2006;24:1117–1123
  6. Zheng J, Venkatesan R, Haacke EM, et al. Accuracy of T1 measurements at high temporal resolution: feasibility of dynamic measurement of blood T1 after contrast administration. J Magn Reson Imaging. 1999;10:576–581
  7. Choyke PL, Austin HA, Frank JA, et al. Hydrated clearance of gadolinium-DTPA as a measurement of glomerular filtration rate. Kidney Int. 1992;41:1595–1598
  8. Boss A, Martirosian P, Gehrmann M, et al. Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements: a phase I trial. Radiology. 2007;242:783–790
  9. Dumoulin CL, Buonocore MH, Opsahl LR, et al. Noninvasive measurement of renal hemodynamic functions using gadolinium enhanced magnetic resonance imaging. Magn Reson Med. 1994;32:370–378
  10. Niendorf ER, Santyr GE, Brazy PC, et al. Measurement of Gd-DTPA dialysis clearance rates by using a look-locker imaging technique. Magn Reson Med. 1996;36:571–578
  11. Niendorf ER, Grist TM, Frayne R, et al. Rapid measurement of Gd-DTPA extraction fraction in a dialysis system using echo-planar imaging. Med Phys. 1997;24:1907–1913
  12. Niendorf ER, Grist TM, Lee FT, et al. Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging. Radiology. 1998;206:791–798
  13. Coulam CH, Lee JH, Wedding KL, et al. Noninvasive measurement of extraction fraction and single-kidney glomerular filtration rate with MR imaging in swine with surgically created renal arterial stenoses. Radiology. 2002;223:76–82
  14. Rohrschneider WK, Haufe S, Wiesel M, et al. Functional and morphologic evaluation of congenital urinary tract dilatation by using combined static-dynamic MR urography: Findings in kidneys with a single collecting system. Radiology. 2002;224:683–694
  15. Montet X, Ivancevic MK, Belenger J, et al. Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging. Invest Radiol. 2003;38:584–592
  16. Pedersen M, Frokier J, Grenier N: Quantitative measurement of renal function using contrast enhanced MRI: an initial experience. Proceedings of Int Scientific Meeting Radionucl Nephr-Urol (ISCORN), La Baule, France, May 16-19, 2004 (Poster M15)
  17. Moricawa S, Inubushi T, Kurumi Y, et al: Feasibility of simple respiratory triggering in MR-guided interventional procedures for liver tumors under general anesthesia. Proceedings of ISMRM 10th Annual Meeting, Honolulu, Hawaii, May 18-24, 2002
  18. Maintz JBA, Viergever MA. A survey of medical image registration. Med Image Analysis. 1998;2:1–36
  19. Denis de Senneville B, Desbarats P, Ries M, et al: Automatic movement correction improves reliability of MR-GFR measurement. Int Scientific Meeting Radionucl Nephr-Urol (ISCORN), Antalya, Turkey, May 9-13, 2007
  20. Sun Y, Jolly MP, Moura JMF: Integrated registration of dynamic renal perfusion MR images. Proceedings of ICIP-IEEE, Singapore, October 24-27, 2004
  21. Michoux N, Vallee JP, Pechere-Bertschi A, et al. Analysis of contrast-enhanced MR images to assess renal function. Magma. 2006;19:167–179
  22. Rusinek H, Boykov Y, Kaur M, et al. Performance of an automated segmentation algorithm for 3D MR renography. Magn Reson Med. 2007;57:1159–1167
  23. Braquelaire JP, Brun L. Image segmentation with topological maps and interpixel representation. J Visual Communication and Image Representation. 1998;9:62–79
  24. Rodriguez Gutierrez D, Diaz Montesdeoca O, Wells K, et al: Partial volume correction for magnetic resonance renography studies. British Chapter of the ISMRM, 12th Annual Meeting, Guilford, August 23-25, 2006
  25. Lee VS, Rusinek H, Bokacheva L, et al. Renal function measurements from MR renography and a simplified multicompartmental model. Am J Physiol. 2007;292:F1548–F1559
  26. Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab. 1983;3:1–7
  27. Annet L, Hermoye L, Peeters F, et al. Glomerular filtration rate: assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney. J Magn Reson Imaging. 2004;20:843–849
  28. Hermoye L, Annet L, Lemmerling P, et al. Calculation of the renal perfusion and glomerular filtration rate from the renal impulse response obtained with MRI. Magn Reson Med. 2004;51:1017–1025
  29. Pedersen M, Dissing T, Deding D, et al: MR renography based on contrast-enhanced T1-mapping. Proceedings of Medicine ISfMRi. International Society for Magnetic Resonance in Medicine, Miami, FL, May 7-13 2005, p 526
  30. Hackstein N, Cengiz H, Rau WS. Contrast media clearance in a single kidney measured on multiphasic helical CT: Results in 50 patients without acute renal disorder. AJR Am J Roentgenol. 2002;178:111–118
  31. Hackstein N, Heckrodt J, Rau WS. Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique. J Magn Reson Imaging. 2003;18:714–725
  32. Hegedus V, Faarup P. Cortical volume of the normal human kidney (Correlated angiographic and morphologic investigations). Acta Radiol Diagn (Stockh). 1972;12:481–496
  33. Chantler C, Barratt TM. Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid. Arch Dis Child. 1972;47:613–617
  34. Brochner-Mortensen J, Rodbro P. Selection of routine method for determination of glomerular filtration rate in adult patients. Scand J Clin Lab Invest. 1976;36:35–43
  35. Blake GM, Roe D, Lazarus CR. Long-term precision of glomerular filtration rate measurements using 51Cr-EDTA plasma clearance. Nucl Med Commun. 1997;18:776–784
  36. Laurent D, Poirier K, Wasvary J, et al. Effect of essential hypertension on kidney function as measured in rat by dynamic MRI. Magn Reson Med. 2002;47:127–134
  37. Lee VS, Rusinek H, Noz ME, et al. Dynamic three-dimensional MR renography for the measurement of single kidney function: Initial experience. Radiology. 2003;227:289–294
  38. Mendichovszky I, Pedersen M, Frøkiær J, et al: How accurate is dynamic contrast-enhanced MRI in the assessment of renal glomerular filtration rate? A critical appraisal. J Magn Reson Imaging (in press)
  39. Jorgensen B, Keller AK, Radvanska E, et al. Reproducibility of contrast enhanced magnetic resonance renography in adolescents. J Urol. 2006;176:1171–1176

PII: S0001-2998(07)00095-5

doi: 10.1053/j.semnuclmed.2007.09.004

Seminars in Nuclear Medicine
Volume 38, Issue 1 , Pages 47-55 , January 2008